Raytek RAYR3IPLUS2MSCL High Temperature Infrared Thermometer with Scope 400 to 2000°C
Raytek RAYR3IPLUS2MSCL Offers
Features
-
A stronger, simpler, safer infrared thermometer with innovative features for enhanced ease-of-use to increase operator efficiency
Combines superior Distance-to-Spot (D:S) ratio with high accuracy and a robust feature set that provides excellent non-contact temperature measurement solutions for process temperature detection and fault previewing
Designed for high temperature applications, it covers a temperature range of 400 to 2000ºC (752 to 3632ºF)
Displays MAX, MIN, DIF, and AVG temperatures
Dual laser for precise measurement of smaller targets, the measurement spot is indicated at the point the two laser beams meet
Red Dot sighting technology for accurate targeting when high temperature targets are not visible using laser sighting alone (The Red Dot light in the scope highlights the area with a red light indicating where the temperature is being measured when the target is bright or red hot and the laser cannot be seen.)
High optical resolution (250:1) ensures accurate temperature readings at longer distances
"Red Nose" heat resistant warning-detector and alarm ensures operator safety and efficiency
Audible alarms for target temperature/ambient temperature/low battery
Compensates for energy reflected by the background around your target so it doesn't affect your reading
Adjustable emissivity and predefined emissivity table
Transmissivity and background temperature compensation
Profile definition to convenient measurement
Curve to display trend with selectable time span
Intuitive user interface for easy parameter set-up, enabling ‘on-site’ display of data analysis and trending
DataTemp® Windows PC software supports real-time communication, data storage, graphing and analysis
Data storage: up to 4,900 data points with location, date, and time stamp
Includes a mobile app for quick data transfer and collaboration, and can be used temporarily as an online thermometer
Fast and easy data transfer to PC or smartphone, using USB or Bluetooth
Longer operational cycle (24 h) on rechargeable batteries
Locking trigger and tripod mount allow for continuous operation
Rugged design reduces risk of damage and minimizes service costs
Raytek Model RAYR3IPLUS2MSCL
Temperature Range | 400 to 2000ºC (752 to 3632ºF) |
Resolution | Below 1000ºC: 0.1ºC |
Accuracy | ±(0.5% of reading +1ºC) (<2700ºC/4892ºF) |
Repeatability | ±(0.3% or reading ±1ºC) |
Emissivity | Adjustable, 0.10~1.00 |
Optical Resolution | 250:1 (Distance to Spot Size) |
Spectral Response | 1.6µm |
Response Time | 40 mSec |
Raytek 3I series | |
Model | Part No |
RAYR3IPIUS2ML | RAYR3I2ML3+ |
RAYR3IPIUS1MSCL | RAYR3I1MSCL3+ |
3ILRSCL2U | |
3I2MSCU | |
3I1MSCL2U | |
3I2MSCL2U | |
3IG5SCU | |
3I1MSCU | |
3I2ML3U | |
RAYR3IPIUS1ML | RAYR3I1ML3+ |
RAYR3IPIUS2MSCL | RAYR3I2MSCL3+ |
3I1ML3U | |
3ILRL3U | |
3ILRSCU | |
3ILTCL3U | |
3ILTDL3U |
-----------------------------------